Posted on

SsangYong Kyron 2005-2015 Factory Service & Shop Manual


Download Link

INSTANT DOWNLOAD (add to cart)


SsangYong Kyron 2005-2015 Factory Service & Shop Manual
Complete workshop & service manual with electrical wiring diagrams for SsangYong Kyron 2005-2015. It’s the same service manual used by dealers that guaranteed to be fully functional and intact without any missing page.

This SsangYong Kyron 2005-2015 service & repair manual (including maintenance, overhaul, disassembling & assembling, adjustment, tune-up, operation, inspecting, diagnostic & troubleshooting…) is divided into different sections. Each section covers a specific component or system with detailed illustrations. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. The printer-ready PDF documents work like a charm on all kinds of devices.

MAKE: SsangYong
YEAR: 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015
MODEL: Kyron
FORMAT: PDF (1.44 GB)

FILELIST:
2005.09 Edition.pdf
2005.10 Edition.pdf
2006.03 Edition.pdf
2006.09 Edition.pdf
2007.04 Edition.pdf
2008.07 Edition.pdf
2010.01 Edition.pdf
2011.01 EWD
Bonus_Material
EURO 4 Service Manual.pdf
EURO IV Service Manual.pdf
Labor Time Guide.pdf
Special Service Tools Catalog.pdf

EXCERPT:
5) Control and Safety Mode ▶ Heater Operations and Safety Mode
– If the fuel pump fails to ignite within 90 seconds after fuel pumping starts, the start procedure is repeated as described. If after a further 90 seconds fuel pumping the fuel pump still fails to ignite, the heater is switched off in fault mode. The controller is locked after a certain number of failed starts.
– If the flame does out by itself during operation, firstly a new start is activated. If the fuel pump fails to ignite within 90 seconds after fuel pumping has started again, the heater is switched off.
– If the heater is overheated (lack of water, poorly vented cooling circuit), the overheating sensor triggers, the fuel supply is interrupted and the heater is switched off.
– The heater is switched off if the lower or upper voltage limit is reached.
– The fuel pump does not start when the glow plug is defect or electrical lead to the dosing
pump is interrupted.
– The fan motor speed is monitored continuously. If the fan motor does not start up, is blocked
or if the speed falls below 40% of the nominal speed, the heater is switched off in fault mode
after 120 seconds.
– It is possible to diagnose the system by connecting the diagnostic device to controller. For
details, refer to the “Diagnosis Procedures” section.