Complete digital official shop manual contains service, maintenance, and troubleshooting information for the Toyota Tacoma 1995-2015. Diagnostic and repair procedures are covered in great detail to repair, maintain, rebuild, refurbish or restore your vehicle like a professional mechanic in local service/repair workshop. This cost-effective quality manual is 100% complete and intact as should be without any missing pages. It is the same factory shop manual used by dealers that guaranteed to be fully functional to save your precious time.

This manual for Toyota Tacoma 1995-2015 is divided into different sections. Each section covers a specific component or system and, in addition to the standard service procedures, includes disassembling, inspecting, and assembling instructions. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. It is in the cross-platform PDF document format so that it works like a charm on all kinds of devices. You do not need to be skilled with a computer to use the manual.

EXCERPT:
1GR-FE EMISSION CONTROL – CANISTER
INSPECTION
1. INSPECT CHARCOAL CANISTER ASSEMBLY
(a) Visually check the charcoal canister for cracks and damage. If there is any cracks or damage, replace the charcoal canister assembly.
(b) Check the charcoal canister operation.
(1) While holding the purge port closed, blow air at 1.67 kPa (17.0 gf/cm2, 0.24 psi) into the vent port, and check that the air flows from the air inlet port.
If the result is not as specified, replace the charcoal canister assembly
(2) While holding the vent port closed, apply a vacuum of 1.10 kPa (8.3 mmHg, 0.32 in.Hg) into the purge port, and check that the air flows from the air inlet port.
If the result is not as specified, replace the charcoal canister assembly
(c) Check for air leakage.
(1) Remove the air hose between ports A and B.
(2) Connect the pressure gauge to the vent port of the charcoal canister.
(3) While holding port B, the purge port and air inlet port closed with your fingers, leave port A open and apply pressurized air at 19.6 kPa (0.2 kgf/cm2, 2.81 psi) into the vent port. Check that the pressure is retained. If the result is not as specified, replace the charcoal canister assembly
(d) Check the leak detection pump.
(1) Check that air flows from port A to ports B and C. If the result is not as specified, replace the pump module.
(2) Apply battery positive voltage across the terminals.
(3) Check that the valve is closed. If the result is not as specified, replace the
pump module.